Design of two way slab in etabs
WebApr 12, 2024 · ETABS is a software program used for the structural analysis and design of buildings. It is capable of modeling various types of structural systems, includin... WebJun 20, 2024 · Hello @ANStructs, @UmarMakhzumi I came across the same situation as @MSKhanand your reply helped me to figure out what's going on in my design. Thanks. Most of the resources (books, online forums, videos) I came across on two way slab indicate that moment "will" be higher in the shorter direction than in the longer direction, …
Design of two way slab in etabs
Did you know?
Web6. DESIGN DETAILS Design of slab 1 L x =2.40 m L y =4.37 m L Y /Lx =1.80 < 2 (Hence slab designed as two way ) Total load on slab = 9.35 kN/m2 Factored moment =10 Kn-m Assuming depth of slab = 150 mm Design of the as under reinforced Slab cover =25 mm Bend the alternative bars@ a distance of L/7 from the face of the wall = 2.40 / 7= 0.342 m WebAbstract - ETABS stands for Extended Three Dimensional Analysis of Building Systems. The main purpose of this software is to design multi-storeyed building in a systematic …
WebApr 16, 2013 · Education Technology Business This document presents an example of analysis design of slab using ETABS. This example examines a simple single story building, which is regular in plan and elevation. It is … WebSLAB DESIGN Reading Assignment Chapter 9 of Text and, Chapter 13 of ACI318-02 Introduction ACI318 Code provides two design procedures for slab systems: 13.6.1 Direct Design Method (DDM) For slab systems with or without beams loaded only ... The basic design procedure of a two-way slab system has five steps. 1. Determine moments at …
WebJan 16, 2014 · I'm trying to model a two-way concrete slab and beam system in etabs. I have the slab elements( h=150 mm) and rectangular beams (400 mm depth x 300 mm width) , but when I view in 3-d, it appears that everything is being modeled from the centerline of the elements. http://www.ce.memphis.edu/6136/PDF_notes/h_slabs.pdf
WebDownload scientific diagram ETABS two-way slab design from publication: Hollow-core precast and two-way solid slabs: Cost estimation and time duration comparison Time and cost are important ...
WebNov 1, 2024 · Without the need of beams, the floor slab system directly supports the columns. In general, the most common challenge encountered when constructing a flat slab is punching shear and flexure... ionwave city of irvingWebJan 8, 2024 · Design of 2 way slab using Etabs Tutorial - Direct Design Method Engineering Learning Platform 18.6K subscribers Subscribe 142 Share 13K views 4 … on the knowledgeWebSolution: Self-weight of the slab= slab thickness* concrete unit weight. = 0.15*24= 3.6 KN/m 2. Total Dead load on Slab= 3.6+0.85= 4.45 KN/m 2. One can distribute service load (unfactored load) to the beam or ultimate distributed load to the slab; use factored load for both dead load and live load of the slab according to the specifications of ... on the knowWebDesign a simply supported one-way solid slab, a span of 4 m, required to support service live load LL=3 KN/m 2 and self-weight only. fc′=28 MPa and f y =420 Mpa. Solution Calculate slab thickness based on Table-1: For simply supported slab, h= L/24= 4000/24= 166.6 mm= 180 m Estimate self-weight of the slab: on the knotWebMar 30, 2024 · Analyse and design the slab based on floor by floor load run down procedure - model the top level and get the reactions and then model the lower level and input the reaction from top level as loading applied on the slab and then another lower level till the lowest floor. ionwave estimatingon the koopman operator of algorithmsWebCircular slabs are more commonly used in the design of circular water tank containers with flat bottom and raft foundations. The analysis of stresses in these slabs is generally based on elastic theory Circular slabs are extensively used during the last decade in many engineering applications due to architectural and/or structural needs. ionwave council bluffs